Measuring Read Sequential vs Random

If you want to measure an existing workload's seq vs random profile in IOPS, there's a pretty simple way.  Run this command (diag mode): stats show readahead.  The part you care about will look like this:

Table 1
readahead:readahead:seq_read_reqs.4K:71%
readahead:readahead:seq_read_reqs.8K:80%
readahead:readahead:seq_read_reqs.12K:78%
readahead:readahead:seq_read_reqs.16K:70%
readahead:readahead:seq_read_reqs.20K:75%
readahead:readahead:seq_read_reqs.24K:75%
readahead:readahead:seq_read_reqs.28K:78%
readahead:readahead:seq_read_reqs.32K:76%
readahead:readahead:seq_read_reqs.40K:77%
readahead:readahead:seq_read_reqs.48K:81%
readahead:readahead:seq_read_reqs.56K:79%
readahead:readahead:seq_read_reqs.64K:98%
readahead:readahead:seq_read_reqs.80K:86%
readahead:readahead:seq_read_reqs.96K:0%
readahead:readahead:seq_read_reqs.112K:0%
readahead:readahead:seq_read_reqs.128K:0%
readahead:readahead:seq_read_reqs.256K:0%
readahead:readahead:seq_read_reqs.384K:0%
readahead:readahead:seq_read_reqs.512K:0%
readahead:readahead:seq_read_reqs.1024K:0%

The first part is garbage: what we care about starts after the period.  The "56k" number is the approximate size of the IOP, and percentage is how many of that size were sequential during your measurement.  Ignore the first whole part, and focus on the percentile.  Just a glace shows you we have at least 75% seq read IOPS averaged across the IOPS sizes. That's good enough for most performance profiling questions.  

I don't think this is particularly useful, but I was asked recently the read random vs sequential throughput measurement as well.  We can also calculate that (roughly) here.  Notice this IOP size count:

Table 2
readahead:readahead:total_read_reqs.4K:94346
readahead:readahead:total_read_reqs.8K:34333
readahead:readahead:total_read_reqs.12K:9669
readahead:readahead:total_read_reqs.16K:8533
readahead:readahead:total_read_reqs.20K:19922
readahead:readahead:total_read_reqs.24K:4563
readahead:readahead:total_read_reqs.28K:4069
readahead:readahead:total_read_reqs.32K:12009
readahead:readahead:total_read_reqs.40K:10299
readahead:readahead:total_read_reqs.48K:5949
readahead:readahead:total_read_reqs.56K:4908
readahead:readahead:total_read_reqs.64K:2675102
readahead:readahead:total_read_reqs.80K:234257

You guessed it.  Multiply the corresponding # of IOPS times the size beside it, multiply that by the percentage that accompanies that IOP size in the first table.  For example:

readahead:readahead:total_read_reqs.32K:12009
readahead:readahead:seq_read_reqs.32K:76%

Calculation 1: 32*12,009 = 384,288Kb

This is your total Kb throughput at that IOP size.

Calcuation 2: 384,288Kb*76% = 292,058Kb

This is the sequential throughput at that IOP size.  Do each calculation for each size, then add all the Calc 1's up and all the Calc 2's.  Finally, divide the sum of the Calc 2's by the sum of the Calc 1's, and you have the percentage of the read throughput which is sequential!

CDOT and Show Mount

FYI, NetApp has a quick workaround to get show mount to work.  From the ReadMe:

This tool provides 7-Mode functionality in Clustered Data ONTAP for the "showmount -e" command as it is executed by an application as a workaround tool until the official ONTAP fix in 8.3.

It is a set of scripts which needs to be copied to the client machines on which the 'showmount -e' command will be executed and hence replacin the original showmount command binary.

The steps to use this showmout wrapper:

1.Move the existing /usr/sbin/showmount to /usr/sbin/showmount_old. This is very important step.

2.Copy the files [NaServer.py, showmount.py, NaErrno.py, NaElement.py, showmount] from showmount_export folder to /usr/sbin.

3.Update the showmount file with proper username and password for the storage virtual machine access

4.Execute showmount -e

Note: Please make sure the LIF "Role" is data and "Firewall policy" is mgmt, when you create the LIF from CLI or If you use system manager to create LIF (storage virtual machine -> select the svm -> configuration -> Network Interface -> create ) and make sure to select "Both" in "Role" screen of the LIF

5.Check the results are coming then try with OVMManager.


http://support.netapp.com/NOW/download/tools/showmount_plugin_cdot/

CDOT 8.2.1 Summary

Take a moment to familiarize yourself with this CDOT 8.2.1 documentation.  There is a TON new and improved in 8.2.1 over 8.2, as well as some cautions.  I’ve highlighted a few here.

https://library.netapp.com/ecmdocs/ECMP1368924/html/GUID-45F85A02-114C-4192-8F1B-A4F50996D307.html

Features:
  • Support for FAS8000 series
  • V-Series feature now called “FlexArray,” a non disruptive on-the-fly licensable feature.
  • Support for qtree exports
  • Storage Encryption support
  • Support for direct attach E-Series configurations
  • Non-Disruptive shelf removal support
  • Log and core dumps available via http:///spi/
  • SQL over SMB3 non-disruptive operations support
  • VMware over IPv6 support
  • Offbox antivirus support
  • Health monitoring of Cluster Switches
  • Increased Max aggr sizes
  • 32-64-bit aggr conversion enhancements
  • Automatic Workload Analyzer, which assesses how the system would benefit from SSDs (Flash Pool)
  • Support for “Microsoft Previous Versions” tab on files (8.2 and later)

Cautions:
  • Some Hitachi or HP XP array LUNs might not be visible.  “In the case of Data ONTAP systems that support array LUNs, if the FC initiator ports are zoned with Hitachi or HP XP array target ports before the storage array parameters are set and the LUNs are mapped to the host groups, you might not be able to see any LUNs presented to the Data ONTAP interface“
  • NFSv2 not supported. Windows over NFSv3 not supported.
  • Verify management software versions are compatible.
  • First VLAN configuration may temporarily disconnect the port.
  • LUN revision numbers change during upgrades.  Windows 2008, 2012 interpret these as new LUNs.  
  • Dedupe space considerations and clearing stale metadata for upgrades.
  • Cautions for proper cluster and vserver peering methods
  • Cautions for proper vol move methods

Tuesday, April 15, 2014

Aggregate Snapshot autodelete_base

Interesting aggregate snapshot name: autodelete_base

The autodelete_base snapshot was created as a fix for BUG 263339: Aggregate snapshot autodelete is leaving me with no snapshots. The filer will automatically create a snapshot called autodelete_base at the aggregate level when a snapshot is removed as a result of autodeletion. This ensures that there is always a new snapshot in the aggregate after a snapshot is deleted.


https://kb.netapp.com/support/index?page=content&id=2011516&locale=en_US

Tuesday, April 1, 2014

SANtricity Walkthough


 Quick walkthrough for anyone unfamiliar with SANtricity.  Names have been changed to protect the innocent, I apologize for the mspaint job but hey, this is a free blog!  You get what you pay for!


1. SANtricity home page

2. Right click an array.  Click manage.
3. Click “view storage array profile.”  You’ll see the chassis SN. These are sometimes missing, sometimes strange combos of letters and numbers, sometimes 70xxxx like FAS systems  When we fix the environment, they’ll all be 70xxx.

4. SANtricity tells you if the system is properly cabled:
"Tray path redundancy"


5. Click hardware tab.  You’ll see the controller firmware version.

6. Exit the view storage array profile.  Click hardware tab. 
Right click a disk you see these options.  This is where you manually fail a drive.

Also notice the menu bar at top has changed: there are a ton of options up there, 
including performance monitoring.

7. Scroll down, you’ll see the controllers.  Right click one, here are your options, 
like locate which blinks lights, or "place" gives you options to “fail over” the 
controller, reboot it, etc if it fails.


8. Configure lets you set the management port IP.


9. The port config window


10.   The tray’s components and their status

E-Series Notes


We've been digging into E-Series as fast as humanly possible, here are some of the basic things that have bee tough to flush out:


  • Impending drive failures: the best practice is to fail the drive manually immediately before replacing it
  • Upgrades:
    • Best practice is to update NVSRAM and Controller Firmware (CFW) at the same time
    • Watch out!  The SANtricity will start running checks and try to upgrade all of the arrays if you do this wrong.  Be careful.  Luckily, it should ask for the array password before upgrading, which gives you a chance to cancel.  
    • If you open the array, go to storage, right click the system, you'll find an "upgrade" option where you can update just that system.  Use this!
    • A precheck is run automatically to detect possible upgrade issues.
    • CFW upgrades are non-disruptive and should take 5-15 minutes per array
    • NetApp recommends not updating disk firmware unless you have a specific reason to
  • Changing array password if you forget it: https://kb.netapp.com/support/index?page=content&id=1013311&actp=search&viewlocale=en_US&searchid=1395157054885
  • Cabling document: https://library.netapp.com/ecm/ecm_get_file/ECMP1394868
    • Looks like each array model has a different cabling schema.
  • E-Series systems have default IP's on 
  •  Default Username: shellUsr, Default Password: wy300&w4

Monday, March 17, 2014

WWPN HBA Swap

Had a great question I wanted to share with you all (names omitted to protect the innocent).  The question was “When doing a motherboard swap or FC HBA swap, why do target WWPN’s not change?”

Answer: Basically WWPN’s are hard coded into the initiator ports but the WWPN’s for target ports are calculated based on the WWNN (see here) and retained statically by ONTAP.

To directly answer the question: “As long as the existing root volume is used in the head swap or upgrade, the same port-to-WWPN mapping applies. For example, port 0a on the replacement head has the same WWPN as the original head. If the new head has different adapter ports, the new ports are assigned new WWPNs.” 
Also interesting: