NetApp Experience: CIFS Error

Here's a new case: we have a filer that we're working on getting data off of to retire it, and ran into an ONTAP bug: this filer is unable to execute CIFS commands that will allow us to rename or offline volumes.  This is a big problem for use because renaming and offline-ing volumes are part of our retirement process.  


Part of the solution for this is called an "NMI reboot."  NMI stands for non-maskable interrupt, which basically means the software in the computer is incapable of ignoring this reboot.  You may be familiar with the small pinhole button on a lot of consumer hardware that would "hard reset" the system: that's it.

This system is a clustered FAS980 running ONTAP 7.2.7.   The plan is to use that pinhole button to reset the filers one at a time: when a reset occurs, the system should failover, and no noticeable downtime should result.  After the reset, we'll do a giveback, let everything settle, and repeat the process on the other system.   

Friday, October 7, 2011

NetApp Experience: Bad Slot

Really very interesting things have happened lately. I had a shelf add that kicked out a ridiculous amount of errors for one disk on the new shelf:

disk.senseError:error]: Disk 2d.53: op 0x28:0000a3e8:0018 sector 0 SCSI:hardware error - (4 44 0 3)


diskown.RescanMessageFailed:warning]: Could not send rescan message to eg-naslowpc-h01. Please type disk show on the console for it to scan the newly inserted disks.


diskown.errorReadingOwnership:warning]: error 46 (disk condition triggered maintenance testing) while reading ownership on disk 2d.53


Disk 2d.53: op 0x28:0000a3f0:0008 sector 0 SCSI:hardware error - (4 44 0 3)
diskown.AutoAssignProblem:warning]: Auto-assign failed for disk 2d.53

The weird thing was that the messages just continued to loop rather than just fail the disk.  We swapped a new disk into that slot, and the old disk into a different slot to see if the disk was bad: turns out, the slot is bad.

We also tried reseating shelf Module B on that shelf.  NetApp Support informed me that "Module A handles communication to the even numbered disks by default, and Module B the odd disks."  I don't think this is true.

We're working with the customer to find a good resolution for this.  Since downtime is difficult to accomplish, we may try to swap out the shelf chassis while the system is running.  We'll see :-)

Thursday, September 29, 2011

NetApp Insights: Shelf Shutdown

Now that we know we can perform a shelf reboot live, we got a bit adventurous.


The question we were trying to answer is "Could we replace/remove a shelf on a live system without causing downtime?"  I used a 3160 cluster in the lab with 4 DS14s in a loop, slowly failed all the disks in shelf 3, and removed ownership on those disks.  At that point, I could shut down/unplug that shelf at will, and neither system complained except noting that they were transitioning to single-path.

I doubt NGS will ever give the plan their full blessing, but it's good to know that it's ok from a technical standpoint. 



Update 1: I also successfully swapped out a shelf chassis in this manner in the lab.  The controllers were totally ok with a new serial number!  No issues that I could find.


Update 2: NGS did in fact OK this action plan twice, but later completely backed out.  There's concern that the system will keep the shelf registered in the OS somewhere.  A possible solution for this is the perform a failover/give back for each node after the shelf removal, since failover/giveback includes a reboot. 

Wednesday, September 28, 2011

An open letter to all University Presidents


An open letter to all University Presidents:

  A budget breakdown my alma mater mailed to me showed that 62% of our budget is staff and faculty salary and benefits. While I applaud the transparency, that makes it pretty hard to look favorably on a donations request: tuition has increased there 29.36% since 2005, in the midst of the greatest economic crisis since the Great Depression.   

  You University Presidents no doubt have many reasons for this: the marketing perspective on price being perceived as value in competition with other universities, competition for good faculty, and I know that few if any students pay the full amount of tuition.  But in the midst of staggeringly high unemployment, American philanthropists have wiser and more deserving places to put their means when your university asks for support.  

  During my 4 years internship, my CEO asked our entire company, himself included, to take a pay freeze.  And we did it willingly because we understood the investment we were making in an institution we believed in.  

 Has your university asked for similar sacrifices from its employees?  Or will the future bear the brunt of this generation's economic mistakes?  More debt on the back of our youth is not the answer to your university's future.  

 Thank you

Thursday, September 22, 2011

NetApp Experience: Shelf Add => Disk Fail

One of my practices when performing a shelf add is to wait in between each step, specifically between unplugging and re-connecting any cables.  My thought process on this has been that the system should be allowed time to settle to its new circumstance, specifically that the controller will need to recognize what paths it is now able to communicate to the disks on.

Digging deeper, one thing I recently learned is that the disk has two ports of communication (referred to as A and B) to the shelf modules, and they negotiate their paths from the disk to the shelf module to the fiber ports on controller.  e.g., Disk 23 port A could be connecting through shelf module B to port 2c, and disk 23 port B could be connecting through shelf module A to port 1b.

All of that is important to understanding the serious issue that failed two disks in a production cluster recently.  A single shelf (DS14mk2 750GB SATA) was connected MPHA to a clustered pair with this configuration:

disk 1d.18: disk port A to shelf module B to port 1d
disk 2b.22: disk port B to shelf module A to port 2b

After unplugging the cable from 1d to shelf module B, there was a 17 second delay and then this:

Cluster Notification mail sent: Cluster Notification from CONTROLLER (DISK CONFIGURATION ERROR) WARNING
Controller> scsi.path.excessiveErrors:error]: Excessive errors encountered by adapter 2b on disk device 2b.18.
Controller> scsi.cmd.transportError:error]: Disk device 2b.22: Transport error during execution of command: HA status 0x9: cdb 0x28:354a07b8:0048.
Controller> raid.config.filesystem.disk.not.responding:error]: File system Disk /aggr2/plex0/rg0/2b.22 Shelf 1 Bay 6 [NETAPP   X268]  is not responding.
Controller> scsi.cmd.transportError:error]: Disk device 2b.18: Transport error during execution of command: HA status 0x9: cdb 0x28:4f5e9748:0048.
Controller> disk.failmsg:error]: Disk 2b.22: command timed out.
Controller> raid.rg.recons.missing:notice]: RAID group /aggr2/plex0/rg0 is missing 1 disk(s).
Controller> raid.rg.recons.info:notice]: Spare disk 2b.27 will be used to reconstruct one missing disk in RAID group /aggr2/plex0/rg0.

Controller> diskown.errorReadingOwnership:warning]: error 23 (adapter error prevents command from being sent to device) while reading ownership on disk 2b.18

Analysis:
These two disks failed as a result of an HBA issue last night.  When a path is disconnected, any disks that are owned over that path are engineered to use the redundant path.  When we disconnected port 1d, the HBA in slot 2 produced errors that halted this normal renegotiation for two of the disks.  Because the disks were not able to operate on the redundant path, the system considered the disks to be in a failed state and began reconstructing that data to spare disks.  When this happened, we halted work to investigate and remediate.  We'll probably just RMA the disks to reduce variables.

NetApp Support recommendation: Re-seat this HBA, which would require a failover/giveback to perform.  Another option would be to replace the HBA (which is what we'll probably do).

Update: NGS (NetApp Support) has changed their minds and now think this is a disk firmware issue.  This disk firmware was backrev'd a couple years still, and their explanation is that iSCSI errors caused by the firmware pile up over time and eventually cross a threshold and cause an HBA to consider that disk incommunicable.  There's no warning on the system that this HBA can't talk to that disk, and all the traffic is routed through the redundant path.

In this case, we had two disks that were in this situation and when I unplugged the return path (the path they were active on) they tried to fail over to the other path and could not.  NGS believes this was just a pure chance, struck by lightning situation.

I'll post the bug report on this soon: the gist of it is that between 40C and 50C, a latching mechanism can get "stuck" and error out, but will quickly recover.  I'm skeptical of this because the highest temperature observed in this shelf was 36C.

2nd Update: As best as I can tell, the disk firmware update did the trick.  We went through with shelf adds last night without seeing the same behavior.  We did, however, see what we believe to be a separate issue.

Monday, September 19, 2011

NetApp Training Brain Dump: Experimenting

Quick notes on things I tested today:
  • If you run a disk fail command, you will have to wait a few hours for the data on that disk to be copied to a spare.
    • There is a -i trigger for the disk fail command that will immediately fail the disk, without copying the data.
  • If you have no spares and you have a disk that is not assigned and is not in use, you have to assign that disk to the controller before it will be used as a spare.  If you have options disk.auto_assign on, it will have already been assigned to a controller.  In either case, you won't need to add the disk to an aggregate: the system detects it as a spare and grabs it in the place of the failed disk.
  • To see how many failed disks you have, use vol status -f
  • To see how many spares you have, use vol status -s
  • If you want to see the status of your disks, disk show won't do it.  You'll need to use disk show -v to see failed disks, and neither will show spare disks as being spare.  
  • You can't resize an aggregate's RAID roups.  You can however use aggr options raidsize to set the size for new RAID Groups that are created for this aggregate.